Equipment Maintenance Guide
The water source used by the HHO equipment is pure water (distilled water is best), tap water or sewage is prohibited
( OH2000-20000 ) Applicable
1. Electrolyzer Cell maintenance
The Oxy-hydrogen electrolyzer is the gas production component of the oxy-hydrogen machine and is the core part of the equipment. When there are too many impurities in the electrolyzer, it will affect its gas production efficiency. If it is not cleaned for a long time, it will shorten the service life of the equipment and cause equipment failure. Therefore, users should pay attention to its daily maintenance during use. The electrolyzer is calculated from the time it is used after replacing the new electrolyte, and 500 hours is a maintenance cycle (the equipment has a timing function, please refer to the instruction manual for details); if the equipment is stopped after a period of use (less than 500 hours), it has been stopped for more than three months when it is used again. It should be maintained before use, and the time within three months of suspension shall prevail.
1. Electrolytic cell cleaning
A、Turn off the power switch of the equipment, unplug the plug or remove the power cord from the external circuit breaker (the three-phase line is not phased during installation).
B. Open the vent valve to release the remaining air inside the equipment (the pressure gauge returns to zero); open the door panel of the equipment and use a 17mm open-end wrench to open the electrolytic cell liquid replacement cover (located on the upper part of the electrolytic cell); then open the electrolytic cell drain valve (located at the bottom of the electrolytic cell, there are two in total), and wait until the electrolyte in the electrolytic cell flows out (it can be discharged into the sewer or the old electrolyte is precipitated and filtered of impurities and matched to the corresponding concentration before use.
C. 1) Use high-pressure water to inject high-pressure clean water from the liquid exchange port to clean the upper part of the electrolytic cell until the discharged liquid is clean water;
2) Inject high-pressure clean water from the left drain valve, open the right drain valve to drain the liquid, and perform high-pressure flushing of the generator until the water is clear; inject high-pressure clean water from the right drain valve, open the left drain valve to drain the liquid, and perform high-pressure reverse flushing of the generator until the water is clear; use compressed air to flush the electrolytic cell from the water injection port, add high-pressure air, open the drain valve to blow out the internal liquid (this step is not required for pure water cleaning)
d. Unplug the line of the liquid level detection sensor, remove the liquid level sensor counterclockwise with a 36MM open-end wrench, and rinse the sensor probe with high-pressure water; and when rinsing the upper part of the electrolytic cell, rinse the sensor installation position with high-pressure water.
2、Electrolyte ratio
A、The main component of the electrolyte used in this equipment is potassium hydroxide (industrial KOH, purity is more than 90%) mixed with pure water (distilled water is best, tap water is prohibited)
B、The blending ratio is a weight ratio of 1:3; that is, 1KG potassium hydroxide (KOH) is mixed with 3KG pure water.
Note: The device will be given a hydrometer when it leaves the factory, which the user can use when mixing. The concentration ratio is 25% to 30%.
C、Steps: Because KOH is highly alkaline and corrosive, it will generate high temperature when dissolved in water, so before mixing, you should prepare a high temperature resistant container (the material requirements are generally stainless steel, high temperature resistant glass, porcelain, etc.), and wear protective equipment (such as protective gloves, masks, etc.)
1)Pour the prepared pure water into the container
2)Add the corresponding KOH
3)Use a stirring rod to stir evenly and wait for the electrolyte to cool to room temperature.
4)Add electrolyte KOH solution into the electrolytic cell
The electrolyte capacity of the model is as follows:
| model | OH2000 | OH3000 | OH5500 | OH7500 | OH10000 | OH20000 |
| Electrolyzer capacity | 24KG | 31KG | 58KG | 80KG | 102KG | 180KG |
2、Steps for adding new electrolyte to the electrolytic cell
A、Close the electrolytic tank drain valve and flushing valve, and connect the equipment power supply.
B、Install the liquid level sensor and restore the line plug
C、Unplug the power supply of the automatic water pump and the automatic water solenoid valve, and turn on the power switch of the equipment.
D、After the equipment self-checks, a bell will sound to indicate a lack of liquid alarm. Add the prepared electrolyte into the electrolytic cell from the liquid exchange port.
E、When the device rings to indicate that it has stopped, the filling process stops (if the device still rings after the filling is completed as shown in the table above, you can quickly restore the power supply of the automatic water filling pump and the automatic water filling solenoid valve to allow the device to automatically fill the water)
F、Restore the power supply of the automatic water adding pump and the automatic water adding solenoid valve with quick plugs, tighten the electrolytic cell liquid replacement cover with a 17MM open-end wrench, cover the equipment door panel, and the liquid replacement is completed.
2. Anti-flashback tank maintenance
The anti-flashback tank is also called a wet anti-flashback device. Its working principle is to extinguish fire with water. When the equipment encounters flashback during operation, the power switch of the equipment should be turned off to stop gas production. The anti-flashback tank will effectively prevent and extinguish the gas that returns to the tank. Therefore, the water level in the tank cannot be lower than the safety level (that is, it cannot be lower than the water level of the water level pipe). In order for its function to work effectively when encountering flashback, its water source must be clean. The internal water source of the anti-flashback tank should be replaced once a month.
1. Discharging liquid
Turn off the power switch of the equipment; open the vent valve to release the remaining air inside the equipment (reset the pressure gauge to zero); open the door panel of the equipment; unscrew the cover of the anti-flashback tank filling port (located above the water level display tube); open the drain valve of the anti-flashback tank (located at the bottom of the anti-flashback tank); after the liquid has drained out, inject high-pressure water from the anti-flashback tank filling port to rinse the inside (the anti-flashback tank has two or three levels, and each level of the anti-flashback device must be cleaned); wait until the water is clear.
2. Add liquid
Close the drain valve at the bottom of the anti-backfire tank, turn on the power switch of the equipment, and the equipment operation screen will prompt that the anti-backfire tank is short of water (this prompt refers to the first-level anti-backfire). Add pure water from the anti-backfire tank filling port, generally add to the two-grid water level displayed on the screen. The other one or two levels as backup anti-backfire should also be filled with water to 90% of the water level tube display; press the reset button on the operation screen, the equipment will perform system self-test, and the detection position will automatically drain from two grids to one grid during the self-test, and the operation screen will display "Working status is normal, press F1 to start gas production"; the filling is completed.
3. Water tank, circuit components and other maintenance
1、Water tank. The function of the water tank is to provide water for the electrolyzer, so that the equipment can work for a long time; therefore, the water stored in the water tank is pure water (distilled water is best). In daily use, users should keep the water source in the water tank clean and regularly check whether the water source in the water tank is clean. If the water source is found to be polluted or there is a lot of deposited dirt, it should be flushed in time. The method is: open the water tank cover, open the drain valve at the bottom of the water tank, and use high-pressure water to flush the dirt. After flushing, add pure water.
2、Circuit components. The circuit components in the equipment mainly include electrolytic power supply, control system, and axial flow cooling fan. Users should regularly (monthly or weekly) check the above parts when using the equipment. After using the equipment for a period of time, it is inevitable that dust will accumulate. If it is not cleaned for a long time, it will affect the heat dissipation of components and even cause equipment failure. Therefore, users should regularly use compressed air to blow and clean the dust covered on the circuit components of the equipment.
3、Other maintenance refers to the cleaning and inspection of the internal structure of the equipment. Users can regularly clean the internal structure of the equipment during daily use, such as checking whether the cleaning is completed after liquid overflow.
4. Leakage Detection
In the process of using hydrogen and oxygen, leakage detection of gas accessories and equipment is a concern. Gas accessories and equipment should be tested every week. The specific methods are as follows:
1. Turn off the gas accessories (such as welding gun, close the gun outlet valve) switch, and the equipment starts to produce gas.
2. Observe whether the pressure gauge pointer rises and whether its value is normal (the hydrogen-oxygen machine will automatically stop producing gas when the pressure is 0.2MPA/0.3MPA, and its error is 0.02MPA)
3. When the equipment operation interface prompts pressure protection and the pressure value is normal, turn off the main power of the hydrogen generator to stop gas production and record the pressure value.
4. Let it stand for more than half an hour. If the pressure value does not change, there is no leakage. If it drops, check the leak point. Method: Cover each interface with soapy water to see if there are bubbles. If there are, it is a leak.
5. When discharging the remaining gas from the equipment, open the switch of the gas accessories (such as the gun valve), block the gas outlet (fire nozzle) with your hand, and immerse the gas accessories in water to check whether there is any leakage.
Okay Energy Technology Co., Ltd